Question Reason Solutions
1 .no action of machine | 1. Amplificatory board no output | Measure output voltage of amplificatory board, and check no voltage, change the board. |
2.fuse burn out | Check or change commutator fuse | |
3.oil pump motor rotation reversion | Exchange two phase | |
4.join device between oil pump and motor | After switch off change it | |
5.pressure valve blocked no pressure | Clear pressure valve, and change hydraulic oil and filter | |
6.oil pump motor burn out and not start | Measure motor winding by omnipotence meter Change motor | |
7. Oil pump is wrong, not retraction oil and increase pressure | Remove oil pump and check Change oil pump |
2. The noise too loud when motor starting | 1.exchange-button has not replacement at starting with action. | Check each selected button Replace switch to original position |
2.preportion valve and relief valve core blocked | Check valve and Clean valve core | |
3. Oil pump is worn out | Remove pump and check Change oil pump | |
11.oil pump sound too laud | 1.filter net has dirty | Clean filter and change oil |
2.quality of absorb oil pipe is poor | Check absorbing oil pipe, Change oil pipe, filter net | |
3.oil pump worn out faster | Check and change oil pump |